No category. Let op! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect installation can cause injury to people and animals and damage to property. The warnings and instructions give important information regarding safety, installation, use and maintenance. Keep hold of instructions so that you can attach them to the technical file and keep them handy for future reference.

Author:Juzuru Samusho
Country:Seychelles
Language:English (Spanish)
Genre:Life
Published (Last):6 February 2015
Pages:357
PDF File Size:10.56 Mb
ePub File Size:12.94 Mb
ISBN:200-2-49921-963-7
Downloads:97463
Price:Free* [*Free Regsitration Required]
Uploader:Muzshura



No category. Let op! Important safety instructions. Carefully read and comply with all the warnings and instructions that come with the product as incorrect installation can cause injury to people and animals and damage to property. The warnings and instructions give important information regarding safety, installation, use and maintenance.

Keep hold of instructions so that you can attach them to the technical file and keep them handy for future reference. Uses other than those indicated herein might cause damage to the product and create a hazard. For all countries outside the EEC, it is advisable to comply with the standards mentioned, in addition to any national standards in force, to achieve a good level of safety. Check that the existing structure meets the necessary strength and stability requirements.

Also disconnect buffer batteries, if any are connected. Bear in mind the standards and directives in force, Good Practice criteria, intended use, the installation environment, the operating logic of the system and forces generated by the automated system. All installations must be visibly identified in compliance with the provisions of standard EN More specifically, hold-to-run controls must be positioned within direct sight of the part being controlled and, unless they are key operated, must be installed at a height of at least 1.

The Firm disclaims all responsibility for the correct operation and safety of the automated system if parts from other manufacturers are used.

Keep nylon bags and polystyrene out of reach of children. For connection to the mains power supply, use: a multicore cable with a cross-sectional area of at least 5x1.

To connect auxiliary equipment, use wires with a cross-sectional area of at least 0. Only qualified personnel professional installer should be allowed to access live parts. Do not throw away your discarded equipment or used batteries with household waste. You are responsible for taking all your waste electrical and electronic equipment to a suitable recycling centre. Anything that is not explicitly provided for in the installation manual is not allowed.

The Firm shall not be answerable for damage caused by failure to comply with the instructions featured herein. The adjustable electronic torque limiter provides anti-crush safety. Manual emergency operation is extremely easy to perform using just a release lever.

Stopping at end of travel is controlled by electromechanical microswitches. If there is a malfunction, make sure that the connected devices are working properly and check the wiring. K See Fig. A Install the electrical system referring to the standards in force for electrical systems CEI , IEC , harmonization document HD and other national standards. B Make a hole in the ground to accommodate the concrete pad, with anchors embedded in the base plate for fastening the gearbox assembly, keeping to the distances featured in FIG.

C - rif. P DANGER - The gate must be fitted with mechanical stops to halt its travel both when opening and closing, thus preventing the gate from coming off the top guide. Said stops must be fastened firmly to the ground, a few centimetres beyond the electric stop point.

Note: the safety edge P1 must be installed so that it is not triggered by the mechanical stops. Connect the live, neutral and earth wire compulsory. The mains cable must be clamped in the relevant cable gland FIG. Q1 and in the grommet FIG. S and the extra low voltage wires must be run through the relevant grommet FIG. Q ref. Wires carrying different voltages must be kept physically separate from each other, or they must be suitably insulated with at least 1mm of additional insulation.

Wires must be secured with additional fastening near the terminals, using devices such as cable clamps. All connecting cables must be kept far enough away from dissipaters. G Built-in Rolling-Code frequency The board has a terminal strip of the removable kind to make maintenance or replacement easier. The jumpers concern terminals: , , If the above-mentioned terminals are being used, remove the relevant jumpers.

Limit switch common Accessories power supply output. Tested safety device power supply output photocell transmitter and safety edge transmitter. Output active only during operating cycle.

Gate opened with this command. If the input stays closed, the leaves stay open until the contact is opened. When the contact is open, the automated device closes following the TCA time, where activated. If not used, leave jumper inserted. The command reverses movement for 2 sec. Antenna input. Use an antenna tuned to MHz. Use RG58 coax cable to connect the Antenna and Receiver. Metal bodies close to the antenna can interfere with radio reception.

While the autoset function is running, the obstacle detection function is not active. If motor force is edited, an autoset opening and closing cycle will need to be performed again. Setting sensitivity incorrectly can result in damage to property and injury to people and animals. By pressing the key again while the automated device is moving a STOP is commanded. I1 Enables Motor Torque to be set automatically.

If the power is suddenly disconnected and then restored the automation performs the operations at autoset speed till the travel limits are identified.

You must run an autoset cycle whenever the slow-down distance T3. S2 Add Pedestrian Key associates the desired key with the pedestrian command. Related documents.

MALPENSA EXPRESS TIMETABLE PDF

BFT DEIMOS BT and QSC D MA Manual

Product Description: The Italian manufactured BFT brand of residential sliding gate automations are available ex stock with more than 10 models to suit all sizes and weights of residential gates. Easy to install. Easy access to internal components during installation and maintenance. Optional battery back-up. QSC - Control panel includes the receiver and has the following functions: 2 or 4 step functioning logic, pedestrian access, 2nd radio channel, photocell cut-out on opening, impulse block opening, automatic closing time, separate adjustment of drive torque limiter during opening and closing phases, operation time adjusted by timer. Dealers wanting to open an account click here: Dealer Signup - Dealers needing volume pricing click here: Dealer Inquiry.

LIVRO AS PERGUNTAS DA VIDA FERNANDO SAVATER PDF

Manual motor bft deimos

Please publish modules in offcanvas position. Instruction manuals Home Downloads Instruction manuals. All instruction manuals. Download Preview. Botticelli - Instruction manual.

PUNCHI COMMISION REPORT PDF

BFT Manuals

.

Related Articles